EMT and RIGID steel fittings

  • EMT compression connectors – steel

    1. Application:  These uninsulated compression connectors are used to bond EMT thinwall conduits to electrical junction boxes or enclosures. Uninsulated, steel compression connectors provide concrete-tight connections when taped,and are rated for electrical applications above 600 volts.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. Labor-saving design allows the electrician to quickly tighten these connectors on EMT conduits. Compression connectors are zinc electroplated for
  • EMT compression connectors – insulated – steel

    1. Application:  These insulated compression connectors are used to bond EMT thinwall conduits to electrical junction boxes or enclosures. Insulated steel compression connectors provide concrete-tight connections when taped and are rated for electrical applications above 600 volts.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. The plastic throat liner ensures that electrical wires and conductors do not get nicked or skinned by sharp metal edges. Compression connectors are zi
  • EMT compression couplings – steel

    1. Application: These compression couplings are used to connect the ends of two EMT thinwall conduits together to extend the electrical raceway. Steel compression couplings provide concrete-tight connections when taped and are rated for electrical applications above 600 volts.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Compression couplings are zinc electroplated for excellent corrosion protection in damp locations.3. Field Names: Compression couplings, electrical coupling, EMT thinwall conduit coupling, conduit co
  • EMT connectors,set screw – steel

    1. Application:  These uninsulated electrical connectors are used in dry locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Uninsulated, steel set-screw connectors provide concretetight connections when taped and properly secured with the included locknut. They are rated for electrical applications above 600 volts.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. Set-screw connectors are made with a versatile combination head screw that can secu
  • EMT connectors, set screw insulated – steel

    1. Application:  These insulated electrical connectors are used in dry locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Insulated, steel set-screw connectors provide concrete-tight connections when taped and properly secured with the included locknut. They are rated for electrical applications above 600 volts.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of the conduit to the designated electrical junction box or enclosure. Set-screw connectors are made with a versatile combination head screw that can securel
  • EMT couplings,set screw – steel

    1. Application:  These electrical couplings are used in dry locations to connect the ends of two EMT thinwall conduits together to extend the raceway. Steel, setscrew couplings provide concrete-tight connections when taped and properly secured with the included set-screws. These steel set-screw couplings are rated for electrical applications above 600 volts.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Set-screw couplings are made with a versatile combination head screw that can securely fasten one conduit to another
  • EMT compression connectors -raintight – steel

    1. Application: These rain-tight compression connectors are used in wet locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Rain-tight EMT compression connectors have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements.2. Advantages:Heavy-gauge construction maintains mechanical protection and solid grounding of the conduit to designated electrical junction boxes or enclosures. Compression connectors are zinc electroplated for excellent corrosion protection in damp locations. Rain-tight EMT comp
  • EMT compression connectors -raintight – insulated

    1. Application: These rain-tight compression connectors are used in wet locations to bond EMT thinwall conduits to electrical junction boxes or enclosures. Rain-tight EMT compression connectors have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements.2. Advantages:Heavy-gauge construction maintains mechanical protection and solid grounding of the conduit to designated electrical junction boxes or enclosures. Compression connectors are zinc electroplated for excellent corrosion protection in damp locations. Rain-tight EMT comp
  • EMT compression couplings -raintight

    1. Application: These rain-tight compression couplings are used in wet locations to connect the ends of two EMT thinwall conduits together to extend the raceway. Rain-tight steel EMT compression couplings have been designed to comply with the new rain-tight test requirements along with the 2008 NEC 358.42 and 314.15 requirements.2. Advantages:Heavy-gauge steel construction maintains mechanical protection and solid grounding of one conduit to another. Compression couplings are zinc electroplated for excellent corrosion protection in damp locations. Rain-tight EMT compression couplings come with
  • Rigid couplings

    1. Application: These threaded couplings are used to join two ends of threaded rigid conduits or IMC conduits together. They can also be used with chase nipples and connectors to bond threaded conduits to electrical junction boxes or enclosures.2. Advantages:Versatile threaded design works with all standard threaded connectors. These couplings are often used as a component to convert flexible metal conduits to EMT thinwall, rigid conduit or liquid-tight conduits by using the related threaded connectors.3. Field Names: Rigid couplings, threaded rigid couplings, heavywall couplings, threaded hea
Leave Your Message